RxQuality¶
SCPI Commands
CONFigure:CDMA:SIGNaling<Instance>:RXQuality:URATe
CONFigure:CDMA:SIGNaling<Instance>:RXQuality:WINDowsize
- class RxQuality[source]
RxQuality commands group definition. 22 total commands, 6 Sub-groups, 2 group commands
- get_urate() → float[source]
# SCPI: CONFigure:CDMA:SIGNaling<Instance>:RXQuality:URATe value: float = driver.configure.rxQuality.get_urate()
Defines update rate for RLP and speech view.
- return
update_rate: Range: 0.25 s to 2 s
- get_window_size() → int[source]
# SCPI: CONFigure:CDMA:SIGNaling<Instance>:RXQuality:WINDowsize value: int = driver.configure.rxQuality.get_window_size()
Sets the active window size in an RLP measurement.
- return
size: Range: 10 s to 240 s , Unit: s
- set_urate(update_rate: float) → None[source]
# SCPI: CONFigure:CDMA:SIGNaling<Instance>:RXQuality:URATe driver.configure.rxQuality.set_urate(update_rate = 1.0)
Defines update rate for RLP and speech view.
- param update_rate
Range: 0.25 s to 2 s
- set_window_size(size: int) → None[source]
# SCPI: CONFigure:CDMA:SIGNaling<Instance>:RXQuality:WINDowsize driver.configure.rxQuality.set_window_size(size = 1)
Sets the active window size in an RLP measurement.
- param size
Range: 10 s to 240 s , Unit: s
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.configure.rxQuality.clone()
Subgroups