RxQuality

SCPI Commands

CONFigure:CDMA:SIGNaling<Instance>:RXQuality:URATe
CONFigure:CDMA:SIGNaling<Instance>:RXQuality:WINDowsize
class RxQuality[source]

RxQuality commands group definition. 22 total commands, 6 Sub-groups, 2 group commands

get_urate()float[source]
# SCPI: CONFigure:CDMA:SIGNaling<Instance>:RXQuality:URATe
value: float = driver.configure.rxQuality.get_urate()

Defines update rate for RLP and speech view.

return

update_rate: Range: 0.25 s to 2 s

get_window_size()int[source]
# SCPI: CONFigure:CDMA:SIGNaling<Instance>:RXQuality:WINDowsize
value: int = driver.configure.rxQuality.get_window_size()

Sets the active window size in an RLP measurement.

return

size: Range: 10 s to 240 s , Unit: s

set_urate(update_rate: float)None[source]
# SCPI: CONFigure:CDMA:SIGNaling<Instance>:RXQuality:URATe
driver.configure.rxQuality.set_urate(update_rate = 1.0)

Defines update rate for RLP and speech view.

param update_rate

Range: 0.25 s to 2 s

set_window_size(size: int)None[source]
# SCPI: CONFigure:CDMA:SIGNaling<Instance>:RXQuality:WINDowsize
driver.configure.rxQuality.set_window_size(size = 1)

Sets the active window size in an RLP measurement.

param size

Range: 10 s to 240 s , Unit: s

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.configure.rxQuality.clone()

Subgroups